High-Efficiency Goodman Side-Discharge Heat Pump System
The Goodman GZV7SA2410 variable-speed inverter heat pump pairs with the AHVE36CP1300 communicating variable-speed air handler to deliver premium comfort, quiet operation, and outstanding energy efficiency. Designed around next-generation R-32 refrigerant, this communicating system automatically adjusts compressor and blower speeds for precise temperature and humidity control while fitting where traditional cube-style condensers won't.
Is a 2 Ton Heat Pump the Right Size?
A 2 ton heat pump provides approximately 24,000 BTU of cooling, making it suitable for many homes between 900 and 1,200 square feet, depending on insulation, ceiling height, windows, sun exposure, and local climate. Because the included AHVE36CP1300 variable-speed air handler can precisely manage airflow, this system also provides exceptional humidity removal in hot, humid climates.
Ideal for: Medium-sized homes, open floor plans, newer construction, townhomes, and homes in hot, humid climates where consistent temperatures and humidity control are a priority.
Need more capacity? Step up to the 3 Ton GZV7SA3610 (36,000 BTU, 1,400–1,800 sq ft) →
Square footage estimates are provided as a general guideline only. Proper equipment sizing depends on factors such as insulation, windows, ceiling height, and local climate. Request free sizing assistance or call 813-885-7999.
What's Included
| Outdoor Heat Pump | Goodman GZV7SA2410 |
|---|---|
| Indoor Air Handler | Goodman AHVE36CP1300 |
| Refrigerant | R-32 |
| Heating | Heat pump with optional electric heat kit |
| Efficiency | 19 SEER2 |
| Factory Charge | Outdoor unit charged for 15 ft. line set |
| Electrical | 208/230V, Single Phase |
| Certifications | AHRI Certified • ETL Listed • ENERGY STAR |
Condenser & Air Handler Features
GZV7SA Variable-Speed Inverter Heat Pump
- Variable-speed inverter-driven swing compressor
- Quiet digitally commutated fan motor
- High-density compressor sound blanket
- Compatible with DTST and GTST connected thermostat and other Goodman communicating equipment
- Diagnostic indicator lights, seven-segment LED display, and fault code storage
- Quiet-mode - provides enhanced acoustical comfort, up to 3 different sound levels (as low as 45dBA)
- Field-selectable boost mode increases compressor speed during unusually high loads
- Field-installed bi-flow filter drier
- Coil and ambient temperature sensors
- Suction pressure transducer
- Heavy-gauge galvanized steel cabinet with grille-style sound control side design
- Custom Ivory white powder-paint finish
- High corrosion (ZAM), unpainted steel bottom frame and legs
- 500-hour salt-spray tested
- Top and side maintenance access
AHVE Variable-Speed Communicating Air Handler
- Electronic Expansion Valve (EEV) for cooling and heat pump applications.
- 7mm evaporator coil tube size
- Variable-speed ECM blower motor
- Provides constant CFM over a wide range of static pressure conditions independent of duct system
- CFM indicator
- All-aluminum evaporator coil
- Multi-position installation (upflow, downflow or horizontal)
- Improved humidity and comfort control
- Factory installed R-32 sensor designed for the lifespan of the coil
- Rigid SmartFrame cabinet
- Field Installed 3kW- 25kW electric heater kit available
- Horizontal or vertical configuration capabilities
- 21" depth for easier attic access
- DecaBDE-free thermoplastic drain pan with secondary drain connections
- Screw-less sides and back helps to reduce condensation when installed in humid locations
- Foil-faced insulation covers the internal casing to reduce cabinet condensation
Specifications & Manuals
Want to understand today's efficiency ratings? Learn about SEER2 ratings →
Frequently Asked Questions
How many square feet will a 2 ton Goodman heat pump cool?
A properly sized 2 ton system provides approximately 24,000 BTU of cooling and commonly serves homes around 900–1,200 square feet. Actual sizing depends on insulation, windows, ceiling height, occupancy, and climate. A Manual J calculation provides the most accurate sizing.
What makes the GZV7SA different from a traditional single-stage heat pump?
The GZV7SA uses an inverter-driven variable-speed compressor that continuously adjusts output instead of simply turning on and off. This results in quieter operation, improved humidity control, greater comfort, lower energy consumption, and more consistent indoor temperatures.
Does this system require a communicating thermostat?
For maximum performance and all advanced features, Goodman recommends pairing this system with a compatible Goodman communicating smart thermostat. Communicating controls allow the indoor and outdoor equipment to automatically optimize airflow, capacity, diagnostics, and efficiency.
Can electric backup heat be added?
Yes. The AHVE36CP1300 accepts optional field-installed electric heat kits ranging from 3 kW up to 25 kW, allowing supplemental heat during extremely cold weather or emergency heating operation.
Is this system quiet?
Yes. The GZV7SA was engineered for low sound levels using an inverter compressor, digitally commutated fan motor, compressor sound blanket, and selectable Quiet Mode that can reduce operating sound to approximately 45 dBA under certain operating conditions.
Why does this system use R-32 refrigerant?
R-32 is Goodman's next-generation refrigerant that offers a significantly lower global warming potential than R-410A while improving heat transfer efficiency. Both the outdoor unit and AHVE air handler are specifically engineered for safe, efficient R-32 operation.
GZV7S Technical Specifications
GZV7S Installation Instructions
GZV7S Parts Manual
GZV7S Service Manual
GZV7S Warranty Certificate
AHVE Technical Specifications
AHVE Installation Instructions
AHVE Warranty Certificate