2 Ton EcoTemp 16 SEER2 R454B Central System W5A5S24AKAWA, WCHL245AB
This EcoTemp system pairs the W5A5S24AKAWA single-stage condenser with the WCHL245AB multipoise ECM air handler, AHRI certified at 16 SEER2 (#214878128). It runs on R-454B, a low-GWP A2L refrigerant, and the air handler has a refrigerant leak detection and dissipation system and a factory-installed TXV. It's cooling only, with electric heat kits from 5 kW up to 15 kW available.
Is a 2 Ton Air Conditioning System the Right Size?
A 2 ton system commonly fits 2-bedroom homes and larger condos around 1,000–1,300 sq. ft. as a general guide.
Sun exposure, ceiling height and insulation can shift that range in either direction. A Manual J load calculation gives the real answer.
Ideal for: 2-bedroom homes, larger condos, townhomes and manufactured homes.
Need more capacity? Step up to the 2.5 Ton EcoTemp 15.5 SEER2 R454B Central System W5A5S30AKAWA, WCHL305AB for a larger load.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | W5A5S24AKAWA — 2 Ton EcoTemp R-454B Air Conditioner |
|---|---|
| Indoor Air Handler | WCHL245AB Multipoise ECM Air Handler (17-5/8" Wide) |
| Application | Cooling-Only Central Air Split System (Electric Heat Kit Optional) |
| Refrigerant | R-454B (Low-GWP A2L Refrigerant) |
| Compressor | Single-Stage Scroll Compressor |
| Metering Device | Factory-Installed R-454B TXV at Indoor Coil |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 13.6 MCA / 20A Max Fuse or Breaker |
| Air Handler Electrical | 208/230V, Single Phase — 3.6 MCA / 15A Max Overcurrent (Without Electric Heat) |
The W5A5S24AKAWA condenser is 35-1/16" tall on a 31-3/16" square base and ships at 163 lbs. The WCHL245AB air handler is 49-5/8" tall, 17-5/8" wide and 22-1/16" deep and ships at 131 lbs. Complete the install with compatible thermostats and copper line sets and fittings.
Condensing Unit & Air Handler Features
W5A5S24AKAWA Outdoor Condensing Unit
- 24,000 BTU/h nominal cooling capacity
- Single-stage scroll compressor (10.3 RLA, 60.2 LRA)
- 73 dBA sound power rating
- 1/10 HP direct drive condenser fan, vertical discharge
- 3/8" liquid and 3/4" vapor service valve connections
- Factory charged with 4.7 lb R-454B for 15 ft of line set
- Long-line capable up to 250 ft total equivalent length
- Low ambient cooling down to 0°F with accessory kit
- Internal pressure relief valve, internal thermal overload and filter drier
- 5-year parts limited warranty, 10 years with registration within 90 days
WCHL245AB Multipoise ECM Air Handler
- Multipoise cabinet: upflow or horizontal left, downflow with kit
- Refrigerant leak detection and dissipation system
- 1/3 HP multi-tap ECM blower motor with five speed taps
- 700 CFM nominal airflow
- Factory-installed R-454B TXV
- Grooved tube, louvered fin aluminum slope coil
- 3/4" FPT condensate connection
- R-4.2 insulation with vapor barrier, prepainted steel cabinet
- Filter rack fits a 16" x 20" filter
- Field-installed electric heat kits, 5 kW up to 15 kW
Specifications & Manuals
Documentation includes the W5A5S single-stage R-454B condenser product specifications and the WCHL ECM fan coil product data, including dimensions, electrical data, airflow tables and heater kits.
Frequently Asked Questions
Why does this 2 ton EcoTemp system reach 16 SEER2?
The rating comes from the matched pair. The W5A5S24AKAWA with the WCHL245AB is AHRI certified at 16 SEER2 (#214878128), near the top of the condenser's 14.3–17.0 SEER2 range.
How tall is the W5A5S24AKAWA condenser?
It's 35-1/16" tall on a 31-3/16" square base and ships at 163 lbs.
Can the WCHL245AB take a 15 kW heat strip?
Yes. EcoTemp lists 5, 8, 10 and 15 kW heaters for the 24 size. The spec sheet calls for at least 775 CFM with the 15 kW heater.
Is there a 2 ton EcoTemp heat pump system?
Yes. The 2 Ton EcoTemp 15.2 SEER2 R454B Heat Pump System W5H5S24AKAAA, WCHL245AB uses the same air handler and adds heating from the outdoor unit.
What type of coil is in the WCHL245AB?
The 2 ton uses a slope coil with grooved tubes and louvered aluminum fins. The 2.5 ton and larger sizes switch to an A-coil.
How much refrigerant does the W5A5S24AKAWA ship with?
It ships with 4.7 lb of R-454B, which covers 15 ft of 3/8" liquid line. Add 0.60 oz per foot of 3/8" line beyond that.

W5A5S Technical Specifications