2.5 Ton EcoTemp 13.4 SEER2 R-454B Heat Pump Package Unit, WJH530000K000B
For mid-size homes and multi-section manufactured homes, the EcoTemp WJH530000K000B delivers 28,600 BTU/h of cooling and 28,400 BTU/h of heat pump heating at 47°F from the same compact 32" x 51" footprint as the 2 ton. It's an R-454B packaged heat pump rated 13.4 SEER2, 11.05 EER2 and 6.7 HSPF2, with a 1/2 HP direct-drive blower moving 1,000 CFM. It gives homeowners and installers a step up in capacity without a bigger pad or a heavier cabinet to set.
Is a 2.5 Ton Heat Pump Package Unit the Right Size?
This size fits cooling loads around 28,000 to 30,000 BTU/h. Typical examples are mid-size ranch homes, double-section manufactured homes, townhomes and small retail or office spaces. It also holds up well in winter, producing 15,700 BTU/h at 17°F before backup heat is needed.
Confirm sizing with a load calculation that accounts for insulation, glass, ductwork and climate. To compare efficiency against an older unit, our SEER2 information page explains the current rating standard.
Ideal for: Double-section manufactured homes, mid-size houses, townhomes and small commercial spaces.
Need more capacity? Step up to the 3 Ton EcoTemp WJH536000K000B Heat Pump Package Unit for 35,200 BTU/h of cooling and up to 15 kW backup heat.
Recommended applications are general guidelines only. Actual system requirements depend on a load calculation, insulation, ductwork, climate, occupancy, and local code requirements. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Packaged Unit | WJH530000K000B — 2.5 Ton R-454B Packaged Heat Pump |
|---|---|
| Cooling Capacity | 28,600 BTU/h (AHRI) |
| Heating Capacity | 28,400 BTU/h at 47°F / 15,700 BTU/h at 17°F |
| Efficiency | 13.4 SEER2, 11.05 EER2, 6.7 HSPF2 |
| Refrigerant | R-454B, Factory Charged (6.75 lb), Leak Detection Dissipation System |
| Compressor | Scroll Compressor With Internal High-Pressure and Overcurrent Protection |
| Indoor Blower | Direct-Drive Multi-Speed, 1/2 HP, 1,000 Rated CFM |
| Duct Connections | Horizontal Supply and Return (Start Collars Provided) |
| Electrical | 208/230V, Single Phase, 60 Hz (20.4 MCA, 30 A Max Overcurrent) |
| Backup Heat | 5, 7.5 or 10 kW Accessory Electric Heater (Sold Separately) |
The WJH530000K000B upgrades to a 1/2 HP blower on a 12" x 9" wheel and a larger outdoor coil while keeping the 32" x 51" footprint (333 lb shipping weight). It ships factory charged with R-454B and includes a leak detection dissipation system. Its accessory heater module mounts on the blower inlet, with single-point power for the heater and the unit.
Heat Pump & Cabinet Features
WJH530000K000B Heating & Cooling Performance
- 28,600 BTU/h cooling, 13.4 SEER2
- 11.05 EER2 rating
- 28,400 BTU/h heating at 47°F (3.7 C.O.P.)
- 15,700 BTU/h heating at 17°F (2.3 C.O.P.)
- 6.7 HSPF2
- 1/2 HP direct-drive blower, 1,000 CFM
- Hermetically sealed scroll compressor
- Demand-based time/temperature defrost
- R-454B with factory leak detection dissipation
- 72 dBA sound rating
WJH530000K000B Cabinet & Installation
- Same 32" x 51" footprint as every WJH5
- Rust-proof composite base, sloped to drain
- Corrosion-resistant painted steel cabinet
- Louvered coil protection
- Front and side service access
- Built-in basepan hand-holds
- Duct start collars provided
- ASHRAE 193 cabinet leakage compliance
- Single-point electrical with accessory heater
- Lightweight 333 lb shipping weight
Specifications & Manuals
Use these documents to review WJH530000K000B heating and cooling performance, heater combinations and electrical data, physical dimensions and warranty coverage.
Frequently Asked Questions
How does the WJH530000K000B compare to the 2 ton WJH524000K000B?
The 2.5 ton delivers 28,600 BTU/h of cooling (versus 24,000) and 28,400 BTU/h of heating at 47°F (versus 23,000). Its 1/2 HP blower moves 1,000 CFM, compared with 800 CFM on the 2 ton's 1/3 HP blower. Both share the same 32" x 51" footprint.
How much heat does the WJH530000K000B provide at 17°F?
EcoTemp rates it at 15,700 BTU/h at 17°F with a 2.3 C.O.P. Accessory electric heaters provide backup and emergency heat on the coldest days.
What breaker does the 2.5 ton WJH5 need without a heater?
EcoTemp lists 20.4 minimum circuit ampacity and a 30 A maximum overcurrent device (HACR breaker) at 208/230V single phase. Adding a heater increases the requirement, so use the electrical table for your heater size.
Does the WJH530000K000B have a rust-proof base?
Yes. It uses a single-piece composite base with an integrated, sloped drain, which eliminates basepan rust and limits standing water that can lead to mold and mildew.
Is the WJH530000K000B serviced from the front or the side?
Both. Multiple side panels plus front access speed up routine tasks such as coil cleaning and electrical checks.
Which homes typically use a 2.5 ton EcoTemp package heat pump?
Double-section manufactured homes, mid-size ranch homes and townhomes, plus small offices and storefronts with outdoor pad space.



WJH5 Technical Specifications