20 Ton Rheem Central Air Split System Three Phase RAWL-240, RHGL-240ZL
20 Ton Rheem Central Air Split System Three Phase RAWL-240, RHGL-240ZL


 
List Price: $13,560.00
Our Price: $11,000.00
AHRI Certificate: Yes
AHRI Number 3243064

Availability: Usually Ships in 3 to 5 Business Days
Product Code: 172290

System Set Up


Commercial Heat Strip

Match Electrical & Size Desired*:


Qty:  
Description Technical Specs
 
20 Ton Rheem Central Air Split System Three Phase RAWL-240, RHGL-240ZL

Rheem Commercial High-Efficiency Condensing Unit
Standard Unit Features
  • CABINET - Galvanized steel with a durable finish. Stamped louvered panels offer 100% protection for the condenser coil.
  • COMPRESSOR - The Scroll Compressor is hermetically sealed with internal overload protection and durable insulation on motor windings. The entire compressor is mounted on rubber grommets to reduce vibration and noise.
  • CONDENSER COIL - Constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities.
  • BASE PAN - Galvanized steel.
  • REFRIGERANT CONNECTIONS - Field piping connections are made through a fixed panel. This allows removal of access panels after piping connections have been made.
  • CRANKCASE HEATERS - Standard, all models. Prevents refrigerant migration to compressor(s).
  • LOW AMBIENT CONTROL - A pressure sensitive fan cycling control to allow unit operation down to 0°F [–17.8°C] is standard.
  • SERVICE VALVES - Standard on liquid and suction lines. Allows outdoor section to be isolated from indoor coil.
  • SERVICE ACCESS - Control box as well as the compressor and other refrigerant controls are accessible through access panels. Control box may be open without affecting the normal operation of the unit. Condenser fan motors are accessible by removing wire grilles.
  • FILTER DRIER - Standard (uninstalled) on all models. Helps ensure refrigerant cleanliness.
  • TRANSFORMER - Step-down type, line to 24 volts. Provides control circuit voltage.
  • CONTACTOR - The contactor is an electrical switch which operates the compressor and condenser fans.
  • HIGH PRESSURE CONTROL - Opens the contactor circuit on high refrigerant pressure; manual reset.
  • LOW PRESSURE CONTROL - Stops compressor operation in the event of loss of refrigerant.
  • CONDENSER FAN MOTOR (Direct Drive) - Ball bearing 1075 RPM motors are mounted to minimize vibration and noise problems. These are permanent split capacitor types. ECM fan motor (10 Ton)
  • TESTING - All units are run tested at the factory prior to shipment. Units are shipped with a holding charge of nitrogen.
  • EXTERNAL GAUGE PORTS - Allows pressures to be checked without removing access panel.
  • COIL LOUVERS - Helps prevent damage to outdoor coils.
  • TIME DELAY - Supplied on tandem compressor models to provide a delay between stages.
  • EQUIPMENTGROUND - Lug for field connection of ground wire.

    Rheem Commercial Air Handler
    Cabinet - Powder coat painted. Matching discharge plenums and decorative supply and return air grilles are available for use when units are to be installed within conditioned space.
    Motor- Inherently protected motors are mounted inside of insulated cabinet to reduce motor noise. A choice of motor horsepowers and drive combinations are available to allow you to meet specified CFM at various static pressures up to 2" [.498 kPa] external static pressure.
    Low Profile - Allows for horizontal installation in most standard drop ceiling applications, and the movement of units through most standard doorways for addition or replacement work.
    Thermal Expansion Valves - Standard all models.
    Filters - One inch [25 mm] throwaway filters are standard, but filter racks are designed to accept either one inch [25 mm] or two inch [51 mm] filters.
    Evaporator Coil -Two circuit, interlaced row split coils are constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities. All coil assemblies are leak tested up to 450 PSIG [3100 kPa] internal pressure prior to installation into units.
    Refrigerant Connections - Field piping connections are made through a fixed post between two side access panels on either side of the unit. Allows flexibility to meet most field conditions as well as full accessibility after the installation is complete.
    Units may be used with two straight cool condensing units or single circuit manifolded in the field using the copper fittings shipped with each unit. The RHGL Air Handler has not been tested, rated or certified to operate with dual remote heat pumps.
    Drain Pan -The galvanized steel drain pan is designed to trap condensate in either vertical or horizontal installations. Condensate drain connections are located on both sides of the unit allowing complete flexibility to meet most field conditions.
    Service Access -Two removable panels on top and each side of the unit are easily removed for access to motors, blowers, sheaves, and filters.
    Horizontal or Vertical - All models are designed for either application and can be installed in either position as supplied from the factory. (See page 22)
    Testing - All units are run tested at the factory prior to shipment.
    Units are shipped with a holding charge of nitrogen.